■FeaturesHigh power factor : 0.95, high efficiency : 9Input : 85~265VACOutput : 500,1000W•Provided in-rush current limiting •N+1 parallel redundant operation
Input voltage range | 85~265VAC (50/60Hz) PFHC range : 85~255VAC (50/60Hz) | |||||||||||
Output voltage/current |
| |||||||||||
Effeciency (typ) | 9 (100VAC, full load), 94% (200VAC, full load) | |||||||||||
Power factor | 0.95 (100VAC/200VAC at full load) | |||||||||||
In-rush current | In-rush current limiting circuit : External limit resistor | |||||||||||
Parallel operation | N+1 redundant operation. Output current balancing (PC terminal) | |||||||||||
Cooling | Conduction cooling (Heatsink& airflow has to be chosen according to instruction manual) | |||||||||||
Operating ambient temperature | Baseplate temperature : -20~+85°C (output derating is different according to condition) Ambient temperature : above -20°C | |||||||||||
Withstand voltage | Input/output terminal to baseplate : 3.0kVAC for 1min | |||||||||||
Safety standard | Approved by UL1950, CSA234 and EN60950 (BSI) | |||||||||||
Functions | Over voltage, Thermal protection, PFHC power on signal (ENA terminal), Inverter good signal (IOG terminal), Auxiliary power supply for external signal(AUX terminal) |
Model name | Nominal Voltage range | Input voltage range | PFHC operation input voltage range | Input current (typ) | Nominal output voltage | Max. output current | Max. output power |
PF500A-360 | 100-240VAC | 85-265VAC (47-63Hz) | 85-255VAC (47-63Hz) | 5.6A | 360VDC | 1.4A | 504W |
200-240VAC | 170-265VAC (47-63Hz) | 170-255VAC (47-63Hz) | 4.0A | 360VDC | 2.1A | 756W | |
PF1000A-360 | 100-240VAC | 85-265VAC (47-63Hz) | 85-255VAC (47-63Hz) | 11.2A | 360VDC | 2.8A | 1008W |
200-240VAC | 170-265VAC (47-63Hz) | 170-255VAC (47-63Hz) | 8.0A | 360VDC | 4.2A | 1512W |